Controller model | CCT-7320 | ||
Signal Detection (Six Channels) |
Dry Contct Input | Raw water no water protection | |
Low pressure protection | |||
High pressure protection | |||
Pure water tank high level | |||
External control model signal | |||
Running reset | |||
Control Port (Five Channels) |
Dry Contact Output | Raw water pump |
SPST-NO Load capacity; AC 220V/3A Max; AC 110V/5A Max; |
Inlet value | |||
High pressure pump | |||
Flush pump | |||
Conductivity over-limit drainage value | |||
Measurement Detection point |
Porduct water conductivity | ||
Measurement Range(CCT-7320) |
Product water conductivity:0.5~20μS/cm, 2~-200μS/cm, 5~-2000μS/cm for selection Product water Temp.: 0~50℃ |
||
Measurement Range(ROC-2316) |
Product water conductivity: 2~200ppm, 10~2000ppm for selection Product water Temp.: 0~50℃ |
||
Temp. compensation |
Automatic compensation, with 25℃ as the reference temperature | ||
Accuracy | 1.5%(FS) | ||
Working environment | Temp.0~50℃, relative humidity: ≤85%RH (none condensation) | ||
Storage environment | Temp.-20~60℃, relative humidity: ≤86%RH (none condensation)) | ||
Power supply | AC220V (±10%) 50/60Hz | ||
Dimension | 96mmx96mmx130mm (HxWxD) | ||
Hole size | 91mmx91mm (HxW) | ||
Installation | Panel mounted,fast installation |
CCT-7320 Single Stage RO Controller
Conductivity cell selection
Conductivity cell cibstant | Part no. |
1.0cm-1 | CON2134-13 |
1.0cm-1 | CON1143-13 |
CON1134-13 can't be userd for food, beverage, medical or sanitary industries
The range of 20/200/2000μS /cm is fixed which can not be changed at field once set by manufacturer.